For a printable version of this instruction sheet, click here.


*Print Version Requires Adobe Acrobat Reader. Click the button above for a FREE download of Acrobat Reader.

 

RESOURCES:
•CADD Prizm Pump
•Enteral Therapy Companion  Pump Procedure
•Enteral Therapy Tube  Feedings/General Care
•Gravity Administration  Procedure
GROSHONG® Catheter Care &  Management Procedure
•Guidelines for safe use of  medical equipment & supplies
HICKMAN® Catheter Care &  Management Procedure
•Implant Tracking Chart
•Kangaroo® 324 Feeding  Pump
•Kangaroo Pet® Feeding  Pump
•Peripheral  Access/Administration of IV  Medication Procedure
•PICC Dressing Change &  Management Procedure
•Port Accessing & Flushing  Procedure
•Ready Med Pump Procedure
•Sabratek Pump Instructions
•Subcutaneous Injection  Procedure
•Syringe Pump Operation &  Procedure

( GROSHONG and HICKMAN
are registered trademarks of
C.R. Bard, Inc. and its related company, BCR, Inc.)

 


SYRINGE PUMP OPERATION AND PROCEDURE

  1. WASH YOUR HANDS.
  2. GATHER YOUR SUPPLIES ON A CLEAN WORK AREA.
  3. CHECK YOUR IV BAG FOR ACCURACY. (PATIENT NAME, DRUG NAME, DOSE, DOCTOR, EXPIRATION DATE).
FILLING (PRIMING) YOUR TUBING
  1. ATTACH THE EXTENSION TUBING TO THE SYRINGE BY REMOVING STERILE PROTECTOR CAPS ON END OF TUBING AND SYRINGE.
  2. GENTLY PUSH THE PLUNGER TO FILL THE TUBING UNTIL A DROP COMES OUT OF THE END OF THE TUBING.
  3. CLAMP THE EXTENSION TUBING.
LOADING THE SYRINGE INTO THE PUMP
  1. PULL BACK PLUNGER LOCK.
  2. PRESS OPEN THE SYRINGE CLAMP AND INSERT THE FILLED SYRINGE. MAKE SURE THE RIM OF THE SYRINGE BARREL IS POSITIONED IN THE CLAMP NOTCH.
  3. SLIDE PLUNGER DOWN TO THE SYRINGE PLUNGER.
  4. ENGAGE THE PLUNGER LOCK OVER THE PLUNGER AND RELEASE.
TO BEGIN YOUR INFUSION
  1. WIPE CAP WITH AN ALCOHOL SWAB.
  2. FLUSH YOUR CATHETER WITH NORMAL SALINE.
  3. WIPE CAP WITH ALCOHOL SWAB.
  4. CONNECT THE TUBING SET TO YOUR CAP.
  5. PRESS THE "POWER ON" BUTTON.
  6. SET THE INFUSION TIME BY PRESSING THE "TIME SET" ARROWS UP OR DOWN. YOUR DOSE SHOULD INFUSE OVER __________MINUTES.
  7. UNCLAMP ALL TUBING AND CATHETER CLAMPS.
  8. PRESS THE "INFUSE" BUTTON
TO END YOUR INFUSION
  1. THE "INFUSION COMPLETE" LIGHT BLINKS AND A CONTINUOUS BEEP IS HEARD.
  2. PRESS "POWER OFF" BUTTON. CLAMP THE TUBING.
  3. REMOVE THE TUBING SET FROM YOUR CATHETER, AND PLACE STERILE CAP OVER THE END.
  4. WIPE YOUR CAP WITH ALCOHOL SWAB.
  5. FLUSH YOUR CATHETER AS INSTRUCTED WITH NORMAL SALINE; THEN WIPE WITH ALCOHOL SWAB AND FLUSH WITH HEPARIN SOLUTION.
AT ANY TIME YOU MAY PRESS THE "STOP INFUSION" BUTTON AND RESTART YOUR INFUSION WITHOUT LOSING YOUR ORIGINALLY SET TIME.

TROUBLESHOOTING / ALARMS
  1. BLINKING GREEN LIGHT - INDICATES NORMAL INFUSION IN PROGRESS.
  2. BLINKING RED ATTENTION LIGHT - INDICATES AN OCCLUSION.
    A. PRESS "STOP INFUSION" BUTTON.
    B. CHECK TUBING AND CATHETER FOR A KINK IN THE TUBING OR A CLOSED CLAMP.
    C. CHECK TO MAKE SURE THE SYRINGE IS PROPERLY LOADED.
    D. PRESS THE "INFUSE" BUTTON TO CONTINUE INFUSION.
    E. IF RED ATTENTION LIGHT CONTINUES AFTER YOU HAVE CHECKED LINE AND PUMP FOR PROBLEMS, CALL HORIZON HEALTHCARE SERVICES.
  3. YELLOW LOW BATTERY LIGHT - 10 HOURS REMAIN ON YOUR BATTERY. REPLACE BATTERIES AT COMPLETION OF THIS DOSE.
    A. SLIDE COVER OFF
    B. INSTALL 4 "C" BATTERIES (POSITIVE SIDE UP)
    C. REPLACE THE COVER

For any questions or concerns, call your home IV nurse according to the instructions your nurse has given you. Horizon Healthcare Services can also be reached 24 hours a day at (717) 544-3590 or toll free at (800) 848-3204
   

 

Disclaimer I Privacy Statement | Privacy Policy

© Horizon Healthcare Services. All Rights Reserved.